Category | Specification |
---|---|
OLED Display | Blue 128 × 32 Pixels |
Timecode Generator Accuracy | TCX0 0.5ppm when free running. In practice, approximately 1 frame drift in 24 hours. Zero ppm when RF locked to a master. |
Supported FPS Modes |
23.976 25 29.97 |
External Power | mini USB 2.0 (5V DC) |
Internal Power | Built-in Li-Polymer (3.7V battery) |
T/C Input | Provided by a Master Timecode Systems product, such as a :pulse base station or another SyncBac PRO. |
T/C Outputs |
USB-C (SyncBac PRO for HERO6 only) HEROBus connector (SyncBac PRO for HERO4 only) Embedded timecode metadata in MP4 camera media |
Multi-Channel Digital Receiver |
UK: 865.050 - 868.550 MHz FCC: 915.050 - 922.200 MHZ JAPAN: 920.600 - 923.300 MHZ |
Range* |
If your SyncBac PRO is using its internal aerial only, the typical range for synchronisation with a master is approximately 200m (256 feet, 219 yards)*. If your SyncBac PRO has an external aerial attached, the typical range is 500-600m (1640-1968 feet, 546-656 yards)*. (SyncBac PRO for HERO4 only) *These are typical ranges. The range can vary and is based on an uninterrupted line of sight. If there are obstacles between a slave and master, the range can be reduced. |